Products

Carbolite CR Clean Room Oven

The CR Clean Room Oven Series of 250 °C ovens comprises nine standard models in sizes from the 30-litre model to the 1810-litre model.

  • Max temp: 250 °C
  • Volume: 30 to 1810 litres
Request a Quote

The CR Clean Room Oven Series of 250 °C ovens comprises nine standard models in sizes from the 30-litre model to the 1810-litre model, which, once processed through a customer’s standard material entry regime, are suitable for operation within an ISO 14644-1 Class 5 environment*.

All sources of particulate contamination are fully sealed. Their easily cleaned stainless steel interiors and gloss white epoxy exteriors prevent the shedding of particulate contamination.

*Federal Standard 209E Class 100 was superseded in 2001 by ISO 14644-1 Class 5

Standard Features

  • 250°C maximum operating temperature
  • 30 to 1810 litre chamber volumes
  • Fully sealed low thermal mass insulation to avoid shedding fibres
  • Fully enclosed brushless fan motor
  • Carbolite Gero 301 controller, with single ramp to set-point & process timer
  • Perforated stainless steel shelves
  • Particle-free silicone rubber door seal
  • Membrane control panel with clear, bright LED display

Technical Details (Models)

CR/30

Max temp (°C) 250
Volume (litres) 30
Temp stability (°C) ±0.2
Temp uniformity (°C) ±3.0 @ 250°C
Heat-up time (mins) 35
Recovery time (mins) 4
Dimensions:
Internal H x W x D (mm)
310 x 310 x 310
Dimensions:
External H x W x D (mm)
685 x 460 x 670
Shelves fitted/accepted 2 / 2
Shelf loading each / total (kg) 10 / 20
Configuration Bench-top
Max power (W) 1000

CR/70

Max temp (°C) 250
Volume (litres) 68
Temp stability (°C) ±0.2
Temp uniformity (°C) ±3.0 @ 250°C
Heat-up time (mins) 35
Recovery time (mins) 4
Dimensions:
Internal H x W x D (mm)
310 x 470 x 470
Dimensions:
External H x W x D (mm)
685 x 620 x 820
Shelves fitted/accepted 2 / 2
Shelf loading each / total (kg) 10 / 20
Configuration Bench-top
Max power (W) 1500

CR/130

Max temp (°C) 250
Volume (litres) 121
Temp stability (°C) ±0.2
Temp uniformity (°C) ±4.0 @ 250°C
Heat-up time (mins) 35
Recovery time (mins) 4
Dimensions:
Internal H x W x D (mm)
550 x 470 x 470
Dimensions:
External H x W x D (mm)
925 x 620 x 820
Shelves fitted/accepted 3 / 5
Shelf loading each / total (kg) 10 / 40
Configuration Bench-top
Max power (W) 2000

CR/180

Max temp (°C) 250
Volume (litres) 170
Temp stability (°C) ±0.2
Temp uniformity (°C) ±5.0 @ 250°C
Heat-up time (mins) 58
Recovery time (mins) 5
Dimensions:
Internal H x W x D (mm)
770 x 470 x 470
Dimensions:
External H x W x D (mm)
1145 x 620 x 820
Shelves fitted/accepted 3 / 7
Configuration Bench-top
Shelf loading each / total (kg) 10 / 50
Max power (W) 2500

CR/220

Max temp (°C) 250
Volume (litres) 227
Temp stability (°C) ±0.2
Temp uniformity (°C) ±5.0 @ 250°C
Heat-up time (mins) 75
Recovery time (mins) 4
Dimensions:
Internal H x W x D (mm)
610 x 610 x 610
Dimensions:
External H x W x D (mm)
1360 940 x 970
Shelves fitted/accepted 3 / 5
Shelf loading each / total (kg) 15 / 45
Configuration Bench-top
Max power (W) 3000

CR/330

Max temp (°C) 250
Volume (litres) 340
Temp stability (°C) ±0.2
Temp uniformity (°C) ±5.0 @ 250°C
Heat-up time (mins) 80
Recovery time (mins) 6
Dimensions:
Internal H x W x D (mm)
915 x 610 x 610
Dimensions:
External H x W x D (mm)
1670 x 940 x 970
Shelves fitted/accepted 4 / 8
Shelf loading each / total (kg) 15 / 60
Configuration Floor-standing
Max power (W) 4500

CR/450

Max temp (°C) 250
Volume (litres) 450
Temp stability (°C) ±0.3
Temp uniformity (°C) ±5.0 @ 250°C
Heat-up time (mins) 75
Recovery time (mins) 9
Dimensions:
Internal H x W x D (mm)
1220 x 610 x 610
Dimensions:
External H x W x D (mm)
1750 x 780 x 850
Shelves fitted/accepted 5 / 11
Shelf loading each / total (kg) 15 / 75
Configuration Floor-standing
Max power (W) 6000

CR/840

Max temp (°C) 250
Volume (litres) 850
Temp stability (°C) ±0.3
Temp uniformity (°C) ±5.0 @ 250°C
Heat-up time (mins)
Recovery time (mins)
Dimensions:
Internal H x W x D (mm)
1525 x 915 x 610
Dimensions:
External H x W x D (mm)
2235 x 1395 x 970
Shelves fitted/accepted 6
Shelf loading each / total (kg) 15 / —
Configuration Floor-standing
Max power (W) 12000

CR/1790

Max temp (°C) 250
Volume (litres) 1810
Temp stability (°C) ±0.3
Temp uniformity (°C) ±5.0 @ 250°C
Heat-up time (mins)
Recovery time (mins)
Dimensions:
Internal H x W x D (mm)
1220 x 1220 x 1220
Dimensions:
External H x W x D (mm)
1930 x 1750 x 1590
Shelves fitted/accepted 5
Shelf loading each / total (kg) 15 / —
Configuration Floor-standing
Max power (W) 18000

Please note
– Uniformity is measured in an empty chamber with vents closed after a stabilization period
– Shelf loadings are based on evenly distributed weight
– Minimum operating temperature approximately ambient +30°C
– Maximum power and heat-up time based on a 240V supply
– The uniform volume is smaller than the overall chamber volume

Content may be subject to modifications or corrections

Subscribe

Known for service-excellence, we don’t just supply the tools, we assist you in gaining proficiency with our products through our dedicated training program.

Scroll to Top