Laboratory ovens of the Peak series 300°C are available as PF fan convection oven and PN natural convection oven models.
FP fan convection oven provides greater temperature uniformity and faster recovery rates than natural convection.
Standard Features
- 300°C (PF 30 to PF 200) or 250°C (PF 400, PF 800) maximum operating temperatures
- 28 to 910-litre chamber volumes
- Equipped with the R38 digital PID temperature controller (PF 30 to PF 200)
- Carbolite Gero 301 controller, with single ramp to set-point & process timer (PF 400 & PF 800)
- Fan convection for rapid heating & recovery & excellent uniformity
- Chemically resistant stainless steel liner
- Two nickel-chrome plated wire shelves (The PF 400 is supplied with 3 wire shelves, the PF 800 with 3 perforated stainless steel shelves)
- Lever latch door & airtight silicone seal
- Compliant with safety standard BS EN 61010-2-010:2003
Options (SPECIFY THESE AT THE TIME OF ORDER)
- A range of sophisticated digital controllers, multisegment programmers and data loggers with digital communication options is available – more information about controllers
- Over-temperature protection (recommended to protect valuable contents & for unattended operation)
- Access port for independent thermocouple
- Accessory shelves & runners
- Heavy-duty reinforced base and shelves
- Cable entry ports
- Variable speed fan control
- Stoving & curing options for the extraction of small volumes of volatile solvents (not compatible with the viewing window option)
- Viewing window (not compatible with stoving & curing option)
- Interior light (not compatible with stoving & curing option)
- Air exhaust fan
- Moisture extraction option (comprising sealed seams and air exhaust fan)
- Stacking frame to enable units to be stacked one upon another
- Lockable door
- Door switch to isolate elements and fan
- Fixed or castor-mounted floor stands
- Low voltage options for use below 220 V
- Routine spares kit
Technical Details (Models)
PF30
Max temp (°C) |
300 |
Min temp (°C) |
Ambient +30 |
Volume (litres) |
28 |
Temp stability (°C) |
±0.2 |
Temp uniformity (°C) |
±5.0 @ 300°C |
Heat-up time (mins) |
40 |
Recovery time (mins) |
4 |
Dimensions:
Internal H x W x D (mm) |
300 x 290 x 320 |
Dimensions:
External H x W x D (mm) |
470 x 665 x 470 |
Shelves fitted/accepted |
2 / 3 |
Shelf loading each / total (kg) |
10 / 20 |
Optional heavy-duty reinforced base max. weight (kg) |
40 |
Optional heavy-duty shelves max. quantity |
2 |
Optional heavy-duty shelves max. weight/shelf (kg) |
20 |
Configuration |
Bench-top |
Air changes/hr |
50 / 360* |
Max power (W) |
1000 |
Holding power (W) |
560 |
Weight (kg) |
37 |
PF60
Max temp (°C) |
300 |
Min temp (°C) |
Ambient +30 |
Volume (litres) |
66 |
Temp stability (°C) |
±0.2 |
Temp uniformity (°C) |
±5.0 @ 300°C |
Heat-up time (mins) |
36 |
Recovery time (mins) |
4 |
Dimensions:
Internal H x W x D (mm) |
400 x 390 x 420 |
Dimensions:
External H x W x D (mm) |
570 x 765 x 570 |
Shelves fitted/accepted |
2 / 5 |
Shelf loading each / total (kg) |
10 / 30 |
Optional heavy-duty reinforced base max. weight (kg) |
60 |
Optional heavy-duty shelves max. quantity |
3 |
Optional heavy-duty shelves max. weight/shelf (kg) |
20 |
Configuration |
Bench-top |
Air changes/hr |
21 / 153* |
Max power (W) |
1500 |
Holding power (W) |
775 |
Weight (kg) |
55 |
PF120
Max temp (°C) |
300 |
Min temp (°C) |
Ambient +30 |
Volume (litres) |
127 |
Temp stability (°C) |
±0.2 |
Temp uniformity (°C) |
±5.0 @ 300°C |
Heat-up time (mins) |
35 |
Recovery time (mins) |
4 |
Dimensions:
Internal H x W x D (mm) |
500 x 490 x 520 |
Dimensions:
External H x W x D (mm) |
670 x 865 x 670 |
Shelves fitted/accepted |
2 / 9 |
Shelf loading each / total (kg) |
10 / 40 |
Optional heavy-duty reinforced base max. weight (kg) |
80 |
Optional heavy-duty shelves max. quantity |
3 |
Optional heavy-duty shelves max. weight/shelf (kg) |
25 |
Configuration |
Bench-top |
Air changes/hr |
11 / 79* |
Max power (W) |
2000 |
Holding power (W) |
900 |
Weight (kg) |
74 |
PF200
Max temp (°C) |
300 |
Min temp (°C) |
Ambient +30 |
Volume (litres) |
230 |
Temp stability (°C) |
±0.2 |
Temp uniformity (°C) |
±5.0 @ 300°C |
Heat-up time (mins) |
42 |
Recovery time (mins) |
5 |
Dimensions:
Internal H x W x D (mm) |
750 x 590 x 520 |
Dimensions:
External H x W x D (mm) |
920 x 965 x 670 |
Shelves fitted/accepted |
2 / 15 |
Shelf loading each / total (kg) |
10 / 50 |
Optional heavy-duty reinforced base max. weight (kg) |
100 |
Optional heavy-duty shelves max. quantity |
4 |
Optional heavy-duty shelves max. weight/shelf (kg) |
25 |
Configuration |
Bench-top |
Air changes/hr |
6 / 44* |
Max power (W) |
2700 |
Holding power (W) |
1180 |
Weight (kg) |
96 |
PF400
Max temp (°C) |
250 |
Min temp (°C) |
Ambient +30 |
Volume (litres) |
460 |
Temp stability (°C) |
±0.2 |
Temp uniformity (°C) |
±5.0 @ 250°C |
Heat-up time (mins) |
85 |
Recovery time (mins) |
25 |
Dimensions:
Internal H x W x D (mm) |
1500 x 605 x 510 |
Dimensions:
External H x W x D (mm) |
1835 x 1025 x 1100 |
Shelves fitted/accepted |
3 / 14 |
Shelf loading each / total (kg) |
10 / 75 |
Optional heavy-duty reinforced base max. weight (kg) |
150 |
Optional heavy-duty shelves max. quantity |
5 |
Optional heavy-duty shelves max. weight/shelf (kg) |
25 |
Configuration |
Floor-standing |
Air changes/hr |
30 |
Max power (W) |
6000 |
Holding power (W) |
2200 |
Weight (kg) |
200 |
PF800
Max temp (°C) |
250 |
Min temp (°C) |
Ambient +30 |
Volume (litres) |
910 |
Temp stability (°C) |
±0.2 |
Temp uniformity (°C) |
±5.0 @ 250°C |
Heat-up time (mins) |
100 |
Recovery time (mins) |
30 |
Dimensions:
Internal H x W x D (mm) |
1500 x 1200 x 510 |
Dimensions:
External H x W x D (mm) |
1835 x 1615 x 1100 |
Shelves fitted/accepted |
3 / 7 |
Shelf loading each / total (kg) |
10 / 100 |
Optional heavy-duty reinforced base max. weight (kg) |
225 |
Optional heavy-duty shelves max. quantity |
5 |
Optional heavy-duty shelves max. weight/shelf (kg) |
75 |
Configuration |
Floor-standing |
Air changes/hr |
15 |
Max power (W) |
9000 |
Holding power (W) |
3500 |
Weight (kg) |
280 |
Please note
– Uniformity is measured in an empty chamber with vents closed after a stabilisation period
– Shelf loadings are based on evenly distributed weight
– The uniform volume is smaller than the total chamber volume
– Maximum power and heat-up times based on a 240V supply
– Stoving and curing options may require increased maximum power
– * When equipped with an optional exhaust fan
Content may be subject to modifications or corrections